Ecolab Ovivo™ Ultrapure Water Treatment Systems

UREA Analyzer

Provides Continuous and Accurate Urea Measurements

Ovivo Ultra-Pure Water+ by Ecolab UREA is a critical contaminant in ultrapure water (UPW) for semiconductor manufacturing because it contributes to total organic carbon (TOC) concentration and can adversely affect photolithography processes.

Ovivo by Ecolab UREA analyzer, a newly innovated product, provides continuous and accurate urea measurements with four sampling channels.

Equipment Details

Ovivo by Ecolab UREA Analyzer allows continuous monitoring, which is capable of capturing seasonal urea variations and adapting the UPW treatment process steps to maximize its removal.

The application is for UPW or deionized water. Other applications depend on the water composition.

We have experience with efficient UREA treatment systems which can be designed regarding specific case and needs of a customer.

The UREA Analyzer has the following important features:

  • Automatic sampling and analysis
  • Continuous (24/7) operation
  • Low consumption of chemicals
  • Wide range of urea concentration
  • Grab sample options
  • Automatic software operation after initial start as well as automatic integration and interpretation
Limit of Detection 1.5 ppb urea
Qualification Range 3 ppb...150 ppb as urea
Sampling Channels 4
Average Measurement Time 60 min / sample
Volume per Sample < 100 mL
Maximum Sample Pressure 10 bar (145 psi)
Voltage 90 - 230 V / 10 A @ 50 - 60 Hz
Power Consumption 450 Watt
Dimensions 60 x 60 x 190 cm (24 x 24 x 75 in)
Operation Mode Automatic/selectable sequence or manual single measurements. Online or grab sample analysis.
Process LC-OND Analyzer for Urea monitoring.

How It Works

Process LC-OND Analyzer for UREA monitoring.

The working principle of UREA Analyzer is based on a chromatographic separation, namely LC-OND (Liquid Chromatography – Organic Nitrogen Detection).

The mobile phase (salt buffer) is pre-cleaned by a specially designed oxidation reactor. A defined volume of aqueous sample is picked up by a loop and injected into the continuous stream of the mobile phase. The sample is then fed to a pump and a chromatographic column where urea is separated from other N-species, like nitrate and ammonium.

After leaving the chromatographic column, the solution is fed to a short-wave UV-oxidation lamp reactor where urea is converted to nitrate.

Nitrate is then selectively detected by a low-wave UV absorption detector (UVD).

All species elute according to their specific retention times. Retention time is used for identification, while peak area units are used for quantification.

Related Product

Ecolab Ovivo™ Ultrapure Water Treatment Systems

THM Analyzer 1501

Trihalomethanes (THMs) are critical contaminants in drinking water and ultrapure water (UPW) and require monitoring as well as efficient removal.

Semi Conductor with Ovivo and Ecolab Logos


Experienced Ultrapure Water Treatment Partners

  • Decades of ultrapure water purification applications development
  • Continuous innovation and extensive range of ultrapure water purification products
  • Comprehensive experience assisting our partners in all phases of ultrapure water production
  • Known for reliable, durable and high-quality system
  • In-depth understanding of water treatment and technologies in the electronics and semiconductor industry

Ovivo Ultra-Pure Water+ by Ecolab